 TECHNICAL
TEMPERATURE AND HUMIDITY MODULE
1 DATA
HF 3223 / HTF 3223
Based on the rugged HS1101 humidity sensor, HF 3223 / HTF 3223 is a dedicated humidity and temperature transducer designed for OEM applications where a reliable and accurate measurement is needed. It features a miniature connector for easy, cost-effective mechanical mounting. Direct interface with a micro-controller is made possible with the module's linear frequency output.
MAIN FEATURES
G G G G G G Size and connector type match existing humidity modules. Stable, linear proportional frequency output from 10 to 95% RH. Calibrated within +/- 5% RH @ 55% RH. Optional 10 K +/- 3% NTC temperature sensor (HTF 3223) Stable characteristics with temperature. High reliability and long term stability.
HF 3223 / HTF 3223
HUMIDITY SENSOR SPECIFIC FEATURES
G G G G G Instantaneous de-saturation after long periods in saturation phase. Fast response time. High resistance to chemicals. Not affected by water immersion. Patented solid polymer structure.
TEMPERATURE SENSOR SPECIFIC FEATURES
G High quality thermistor G Stable G High sensitivity
MAXIMUM RATINGS
Ratings Symbol Value Unit
Storage Temperature Storage Humidity Range Supply Voltage (Peak) Humidity Operating Range
Tstg RHstg Vs RH
-40 to 85 0 to 100 7 0 to 99 -30 to 80
C % RH Vdc % RH C
Temperature Operating Range Ta
CHARACTERISTICS
Humidity sensor
Humidity metrology range Relative Humidity accuracy (10 to 95 % RH) Voltage supply Nominal output @ RH = 55 % Current consumption Temperature coefficient (0 to 60 C ) Averaged Sensitivity from 33 % to 75 % RH Sink current capability Recovery time after 150 hours of condensation Humidity Hysteresis Long term stability Response time (33 to 76% RH, static, @63 %)
(Ta = 25C, Vs = 5.0 Vdc +/- 5%, RL > 100 K unless otherwise stated)
Characteristics
Symbol
Min.
Typ.
Max.
Unit.
RH RH Vs Fout Ic Tcc
10 +/- 5 4.75 8670 5.0 8750 +/- 0.1 -16 - 18 100 10 +/-1.5 0.5
95 +/- 10 5.25 8830 0.1 -19
% RH % RH VdC Hz mA % RH/C Hz/% RH A s % RH % RH/yr s
Fout / RH
Is t
10
Humirel Sensor Device Data / HPC014 Rev G July 2001
TECHNICAL
Relative Humidity Accuracy of HF 3223 / HTF 3223
2 DATA
Maximum error in % RH
Relative Humidity in %
Modeled Signal output (Linear Reference curve) : Typical response look-up table
RH (%) Fout (Hz) RH (%) Fout (Hz) 55 8750 60 8660 0 5 10 9560 65 8570 15 9470 70 8480 20 9380 75 8390 25 9290 80 8300
Fout = 9740 - 18*RH with Fout in Hz and RH in %
30 9190 85 8210
35 9110 90 8120
40 9020 95 8030
45 8930 100
50 8840
Typical , Minimum and Maximum Frequency Values for HF 3223 / HTF3223
Fout in Hz
Relative Humidity in %
Calibration data are traceable to NIST standards through CETIAT laboratory.
Humirel Sensor Device Data / HPC014 Rev G July 2001
TECHNICAL
CHARACTERISTICS
Temperature sensor
Characteristics
(Ta = 25C)
3 DATA
Unit.
Symbol
Min.
Typ.
Max.
Nominal resistance @ 25C Beta value : B25/100 Temperature measuring range Nominal Resistance Tolerance B value tolerance Response Time B Ta Rn B 3600 - 30
10 3730 2 3 10 3800 80 3
k C % % s
Typical temperature output
Depending on the needed temperature measurement range and associated accuracy, we suggest two methods to access to the NTC resistance values. The actual characteristic of an NTC thermistor can, however, only be roughly described by the exponential relation,as the material parame ter B in reality also depends on temperature. So this approach is only suitable for describing a restricted range around the rated temperature or resistance with sufficient accuracy.
1
NTC resistance in at temperature T in K NTC resistance in at rated temperature in K Temperature in K B value,material-specific constant of the NTC thermistor Base of natural logarithm (e =2.71828)
2 For practical applications a more precise description of the real R/T curve may be required. Either more complicated approaches (e.g the Steinhart-Hart equation) are used or the resistance/ temperature relation as given in tabulated form. The below table has been experimentally determined with utmost accuracy for temperature increments of 1 degree.
Temperature C -30 -29 -28 -27 -26 -25 -24 -23 -22 -21 -20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3
Resistance (ohm) 144790 136664 129054 121925 115243 109030 103115 97565 92354 87460 82923 78581 74497 70655 67039 63591 60381 57356 54503 51813 49204 46767 44467 42296 40247 38279 36455 34731
Max. Deviation 16636 15444 14343 13325 12383 11516 10705 9953 9257 8612 8020 7463 6947 6468 6023 5606 5222 4865 4533 4225 3932 3662 3411 3177 2960 2756 2568 2393
Temperature C -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Resistance (ohm) 33100 31557 30029 28627 27299 26042 24852 23773 22708 21698 20739 19829 18959 18128 17338 16588 15876 15207 14569 13962 13384 12834 12280 11777 11297 10840 10404 10000
Max. Deviation 2230 2078 1932 1799 1675 1560 1452 1355 1261 1174 1093 1017 946 879 817 759 705 654 607 563 522 484 447 413 382 353 325 300
Temperature C 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53
Resistance (ohm) 9600 9218 8853 8506 8178 7866 7568 7283 7011 6734 6484 6244 6015 5796 5575 5373 5180 4995 4817 4636 4473 4316 4166 4021 3874 3737 3606 3481
Max. Deviation 300 300 299 297 296 294 292 290 287 284 281 278 275 271 267 264 260 257 253 248 245 241 237 233 229 225 221 217
Temperature C 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80
Resistance (ohm) 3360 3237 3126 3019 2917 2819 2720 2629 2542 2458 2378 2304 2229 2158 2089 2022 1960 1898 1839 1782 1727 1673 1622 1573 1526 1480 1432
Max. Deviation 213 208 204 200 197 193 189 185 182 178 175 171 168 165 161 158 155 152 149 146 143 140 138 135 132 130 127
Humirel Sensor Device Data / HPC014 Rev G July 2001
TECHNICAL
QUALIFICATION PROCESS
Resistance to physical and chemical stresses
G G
4 DATA
HF3223 / HTF3223 has passed through qualification processes of HUMIREL including vibration, shock, storage, high temperature and humidity, ESD.
Additional tests under harsh chemical conditions demonstrate good operation in presence of salt atmosphere, SO2 (0.5%, H2S (0.5%), 03, NOx, NO, CO, CO2, Softener, Soap, Toluene, acids (H2SO4, HNO3, HCI), HMDS, Insecticide, Cigarette smoke, a non exhaustive list. HF3223 / HTF3223 is not light sensitive.
G
PACKAGE OUTLINE HF3223 / HTF3223
Dim
A
B
C
D
E
F
G
Min 9.7 8.5 Max 10.8 9.5 Dim Min Max
Connector type : JST model S4B-ZR
to be mated with ZHR or 04ZR type female connectors
33.5 21.5 1.55 3.5 1.45 34.5 22.5 1.65 3.9 1.55 K L M N 3.5 4.5 3.0 3.4
H 4.5 4.7
J
7.3 29.5 13.8 3.5 7.7 30.5 14.2 4.5
Dimensions in millimeters
ORDERING INFORMATION (Multiple Package Quantity of 40 pieces) : HF3223 : Humidity Frequency output alone HTF3223 : Humidity Frequency output + NTC (Temperature direct output)
SAMPLE KIT OF HF 3223 / HTF 3223 IS AVAILABLE THROUGH HUMIREL WEB SITE
www.humirel.com
email : sales@humirel.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsability is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Humirel reserves the right to make changes without further notice to any product herein. Humirel makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Humirel assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters, including Typical must be validated for each customer applications by customer's technical experts. Humirel does not convey any license under its patent rights nor the rights of others. Humirel products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other application intended to support or sustain life, or for any application in which the failure of the Humirel product could create a situation where personal injury or death may occur. Should buyer purchase or use Humirel products for any such unintended or unauthorized application, Buyer shall indemnify and hold Humirel and its officers, employees, subsidaries, affiliates and distributors harmless against all claims, costs, damages and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of presonal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Humirel was negligent regarding the design or manufacture of the part.Humirel is a registred trade mark of Humirel.
Humirel Sensor Device Data / HPC014 Rev G July 2001